Sectional Garage Door Installation / Measuring Guide


Please find below some guidelines on measuring for a sectional garage door installation. A full installation guide can also be download in PDF format:

Installation Instructions (8.82 MB)

Measuring for a Hormann Garage Door


1. Hormann garage doors are stated in terms of the internal dimensions of the door frame. For example: If the internal frame to frame dimension is 2133mm and the floor to the underside of the frame crossbar dimension is 1980mm, then the door size required is 2133mm x 1980mm. See Figure A.

2. Hormann sectional doors are fitted to the rear of the brick wall or pillar. See Figure B.

3. With a Hormann sectional door, a minimum of 90mm is required behind the brick or pillar on either side of the door opening.

4. Hormann garage doors require a 70mm square timber frame or a factory fitted steel frame. All Hormann sectional doors come complete with a 90mm steel frame (2 uprights and a single crossbar). Note: The door size does not include the size of the frame.

measuring guide
Hormann Door Spring Systems and Minimum Ceiling Heights
ceiling heights

Spring System

Door Width Size

Minimum Ceiling Height
with Manual Opening

Minimum Ceiling Height
with Automatic Opening

Minimum Clearance Required
Either side of door opening

 

 

 

 

 

Z

width up to 10ft

6'6" door – 2100mm

2125mm

90mm

 

 

7' door – 2225mm

2250mm

90mm

N

width over 10ft

6'6" door – 2210mm

2210mm

90mm

 

 

7' door – 2335mm

2335mm

90mm

L

width over 10ft

6'6" door – 2100mm

2125mm

90mm

 

 

7' door – 2225mm

2250mm

90mm


Note: These dimensions are based on using Hormann remote door openers.  If you wish to use a different make of remote door opener, then ensure that you add 10mm to the dimensions above.